top of page

User Interfaces of Unknown Provenance (UOUP) in Medical Devices

User Interfaces of Unknown Provenance (UOUP) in medical devices refers to situations where the usability aspects of a device are not clearly documented or traceable. This lack of clear usability documentation can arise in several scenarios, such as when devices are acquired through mergers and acquisitions, when legacy systems are integrated into new products, or when usability testing records are lost or incomplete.  This blog explores the crucial intersection of usability engineering and UOUP in medical devices, offering insights into navigating compliance, mitigating risks, and optimizing user interface design to enhance overall device performance and safety.

User Interfaces of Unknown Provenance UOUP Medical Devices

What is User Interfaces of Unknown Provenance (UOUP)?

UOUP refers to a user interface that is used in a medical device, but its design and development history are unknown or not fully documented. This can occur when components are sourced from third-party suppliers or when integrating legacy systems into new devices.

Key Scenarios for User Interfaces of Unknown Provenance (UOUP) Application

Manufacturers may apply the UOUP process in several scenarios, including:

  • Legacy Devices: Medical devices already on the market that were not originally developed under the IEC 62366:2006 standard.

  • Minor Changes: Devices undergoing minor modifications that do not warrant a full usability engineering process.

  • Commercial Components: Devices incorporating commercially available components that lack specific usability engineering documentation.

Key Issues with User Interfaces of Unknown Provenance (UOUP) in Medical Devices

  • Lack of Documentation: The history of usability evaluations, user feedback, and design iterations may be missing, making it difficult to assess the device's usability comprehensively.

  • Unclear User Requirements: Without documented usability studies, the specific needs, preferences, and limitations of the end-users might not be well understood or considered in the device's design.

  • Regulatory Challenges: Regulatory bodies like the FDA and the EU MDR require detailed usability engineering files for medical device approval. UOUP poses a significant challenge in meeting these regulatory requirements.

  • Safety Risks: Undocumented usability can lead to unidentified user errors, inefficiencies, and potential safety hazards, particularly critical in the medical field where device misuse can have severe consequences.

Facilitations by IEC 62366:2006 and 62366-1:2015

UOUP specifically refers to user interfaces that were approved and introduced to the market before the implementation of the 2015 revision of IEC 62366-1. These interfaces do not have documentation that complies with the updated usability engineering requirements set forth in the latest standard. Consequently, they are considered of "unknown provenance" concerning their usability engineering history. This designation applies to user interfaces or parts thereof that lack adequate documentation of a suitability-oriented development process, as specified by the international standard IEC 62366-1.

The facilitations provided by these standards allow manufacturers to streamline the evaluation process for UOUP. Specifically, certain steps such as usability specification, verification, and validation may be modified or omitted for unchanged components under the legacy guidelines. 

Addressing User Interfaces of Unknown Provenance (UOUP) in Medical Devices

Addressing Usability of Unknown Provenance (UOUP) in medical devices involves conducting thorough retrospective usability evaluations, understanding current user needs, managing risks, and creating comprehensive usability documentation to ensure both user safety and regulatory compliance. The evaluation process outlined in Annex C of IEC 62366-1:2015 provides clear steps for assessing UOUP.

  • Use Specification: Define the intended medical indication, user profiles, use environments, and operating principles. Conduct thorough user research to understand the needs and contexts of the device’s current user base. Use this information to fill in gaps left by the missing documentation.

  • Post-Production Information Analysis: Review post-market surveillance data to identify potential use errors and hazards related to usability.

  • Use-Related Risk Analysis: Evaluate identified risks associated with user interaction and document them appropriately. Conduct a thorough risk assessment focused on the user interface, considering factors such as complexity, user training requirements, and potential use errors. Implement risk control measures to mitigate identified risks.

  • Risk Control: Implement measures to mitigate identified risks, ensuring they are reduced to an acceptable level.

  • Residual Risk Evaluation: Re-evaluate the overall residual risk considering all risk control measures implemented.

  • Conducting Retrospective Usability Testing: Perform usability testing with current users to gather data on how the device is used in real-world scenarios. Identify any usability issues and gather feedback to inform potential redesigns or improvements.Perform usability testing and validation activities specific to the user interface of devices incorporating UOUP. This should involve representative users and simulate real-world conditions to identify potential usability issues.

Key Practices for Successful User Interfaces of Unknown Provenance (UOUP) compliance

Effective usability engineering hinges on several key best practices that ensure products meet user needs and expectations. Here are the few best practices for usability compliance -

  • Creating New Usability Documentation: Document all new usability testing, user feedback, and design changes. Ensure that new usability engineering files meet regulatory requirements and can be traced back to specific user needs and design decisions. 

  • Regulatory Compliance: Engage with regulatory experts to ensure that the retrospective usability evaluations and new documentation comply with current regulatory standards. Address any gaps identified during the compliance review process.

  • Training and Support: Provide training and support to users to mitigate any usability issues identified during retrospective evaluations. Ensure that users are aware of best practices for using the device safely and effectively.

  • Collaboration with Suppliers: Establish clear communication and collaboration with suppliers of UOUP components or software to ensure that their products meet MDR requirements and provide necessary documentation and support.

  • Continuous Improvement: Implement processes for continuous improvement based on feedback from users and post-market surveillance data. This ensures that any usability issues or user interface concerns are addressed promptly.

The UOUP process provides a structured approach for manufacturers to retrospectively evaluate and validate user interfaces that lack comprehensive usability engineering documentation. By adhering to the principles outlined in IEC 62366-1, manufacturers can ensure compliance with regulatory requirements while maintaining efficiency in the evaluation of existing medical devices. This process underscores the importance of continuous improvement and risk management in medical device usability, ultimately enhancing patient safety and user satisfaction in the healthcare environment.

Ready to streamline your medical device's compliance journey with expert guidance? Partner with Artixio today to navigate the complexities of UOUP and ensure your device meets rigorous usability standards. Contact us to learn more about our comprehensive usability engineering solutions and how we can assist your product development process.