top of page

ISO 62366 Human Factor Usability Engineering : A Guide for Medical Device Manufacturers

Usability engineering is an essential aspect of medical device design, ensuring that devices are effective, safe, and user-friendly. ISO 62366 is the international standard that provides guidelines and requirements for applying usability engineering to medical devices. ISO 62366  outlines the process for integrating usability engineering into the development of medical devices.  In this blog, we'll delve into the key components of ISO 62366, its importance, and how it impacts the medical device industry.

ISO 62366 Human Factor Usability Engineering

What is ISO 62366 ?

ISO 62366 is an international standard focused on usability engineering for medical devices. It provides a framework for manufacturers to design devices that are easy to use and minimize the risk of user error, thus enhancing overall patient safety by identifying and mitigating potential use errors. The standard is divided into two parts:

  • ISO 62366-1:2015 - Application of usability engineering to medical devices.

  • ISO/TR 62366-2:2016 - Guidance on the application of usability engineering to medical devices.

The ISO 62366 Standard has been amended in June 2020 to ensure the medical devices brought into the market are safe for intended use.

Key Components of ISO 62366 Human Factor Usability Engineering

ISO 62366-1 outlines a systematic approach to integrating usability engineering into the medical device development process. The key components include:

Usability Engineering Process : The usability engineering process is central to ISO 62366 and involves several systematic steps to ensure that usability is considered throughout the medical device development lifecycle. The main steps are:

  • Preparation of a Usability Engineering Plan: This involves defining the scope, objectives, and methods for usability activities, ensuring they are aligned with the overall development process.

  • User and Use Environment Analysis: Understanding who will use the device, the context in which it will be used, and any environmental factors that could impact usability.

  • Task Analysis: Breaking down tasks users will perform with the device to identify potential challenges and ensure that all user interactions are considered.

  • Identification of Use Scenarios: Describing realistic scenarios in which the device will be used to ensure that all potential use conditions are considered.

User Interface Design : Designing the user interface involves creating an interface that is intuitive and easy to use. This includes:

  • Development of User Interface Specifications: Detailed specifications that outline how the user interface should function, including visual, auditory, and tactile elements.

  • Prototyping and Iterative Design: Developing prototypes and refining them through iterative testing and feedback to ensure they meet usability requirements.

  • Incorporating Usability Principles: Applying principles such as consistency, feedback, and simplicity to enhance the user experience.

Risk Management : Risk management is integrated with usability engineering to ensure that potential use errors do not compromise patient safety. This involves:

  • Identification of Hazardous Situations: Identifying potential hazards associated with the use of the device and understanding how user errors could lead to these hazards.

  • Risk Control Measures: Implementing measures to mitigate identified risks, which may include design changes, user training, or enhanced instructions for use.

  • Usability-Related Risk Analysis: Continuously assessing usability-related risks throughout the development process to ensure that new risks are identified and managed.

Verification and Validation : Ensuring that the device meets usability requirements involves two key activities:

  • Usability Verification: Confirming that the user interface meets the specified requirements. This is typically done through inspections, reviews, and testing of the user interface components.

  • Usability Validation: Demonstrating that the device can be used safely and effectively by the intended users in the intended use environment. This usually involves user testing under realistic conditions.

Documentation and Traceability : Maintaining comprehensive documentation is essential for demonstrating compliance with ISO 62366. This includes:

  • Usability Engineering File (UEF): A collection of all usability engineering documentation, including the usability engineering plan, user and task analyses, risk management activities, and results of verification and validation activities.

  • Traceability: Ensuring that all usability requirements and risk control measures are traceable to specific user needs, tasks, and identified risks.

Usability Evaluation : Conducting usability evaluations throughout the development process to ensure that the device meets user needs and usability goals. This includes:

  • Formative Evaluations: Conducted during the development process to identify usability issues and inform design improvements.

  • Summative Evaluations: Conducted at the end of the development process to confirm that the device meets its usability requirements and can be used safely and effectively.

Continuous Improvement : ISO 62366 encourages continuous improvement by:

  • Gathering User Feedback: Collecting feedback from users during and after device development to identify potential areas for improvement.

  • Post-Market Surveillance: Monitoring device performance in the market to identify and address any usability issues that may arise.

ISO/TR 62366-2: Guidance on Application

ISO/TR 62366-2 provides practical guidance on implementing the usability engineering process described in ISO 62366-1. It offers detailed explanations, examples, and best practices to help manufacturers apply usability engineering principles effectively.

Integration with Other Standards

ISO 62366 is designed to work in conjunction with other medical device standards, particularly ISO 14971, which focuses on risk management. Together, these standards provide a comprehensive approach to ensuring medical device safety and performance.

Challenges in Implementing ISO 62366

While ISO 62366 offers a clear framework, manufacturers may face challenges in its implementation:

  • Resource Intensive: Usability engineering can be resource-intensive, requiring dedicated time and expertise.

  • Complex User Environments: Medical devices are used in varied and sometimes unpredictable environments, making it difficult to anticipate all potential use errors.

  • Continuous Updating: Keeping usability documentation and practices up-to-date with evolving user needs and regulatory requirements.

ISO 62366 is a vital standard for the medical device industry, guiding manufacturers in designing user-friendly, safe, and effective devices. By following the usability engineering process outlined in ISO 62366, manufacturers can enhance device usability, reduce the risk of user error, and improve overall patient safety. Implementing this standard not only helps in compliance with regulatory requirements but also contributes to the creation of better, more reliable medical devices. For medical device manufacturers, embracing ISO 62366 is an investment in quality and safety, ultimately leading to improved healthcare outcomes and user satisfaction. By prioritizing usability, manufacturers can ensure that their devices are not only technically sound but also intuitive and easy to use, thereby fostering trust and confidence among healthcare professionals and patients alike.

For top-notch usability engineering services that enhance your medical device's market readiness, reach out to Artixio today. Contact us at info@artixio.com to learn more!

 

bottom of page